Sign In | Join Free | My himfr.com
himfr.com

Shanghai S&D International Dental Co., Ltd.

Specialize in Dental Industry over 18 Years Producing Diamond Burs & Acrylic Resin Teeth with high cost-performance Acceptable for L/C, DP and DA Term Instant Online Serve your Inquiries

Verified Supplier

3 Years

Home > Rotary Endodontic Files >

Dental Heat Treatment Rotary Endo Files Systems P Glider File Instrument For Root Canal Treatment

Shanghai S&D International Dental Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Dental Heat Treatment Rotary Endo Files Systems P Glider File Instrument For Root Canal Treatment from wholesalers
     
    Buy cheap Dental Heat Treatment Rotary Endo Files Systems P Glider File Instrument For Root Canal Treatment from wholesalers
    • Buy cheap Dental Heat Treatment Rotary Endo Files Systems P Glider File Instrument For Root Canal Treatment from wholesalers

    Dental Heat Treatment Rotary Endo Files Systems P Glider File Instrument For Root Canal Treatment

    Ask Lasest Price
    Brand Name : S&D
    Model Number : #16/02
    Certification : TUV CE, ISO13485, ISO9001
    Price : Negotiable
    Payment Terms : T/T, Western Union, MoneyGram, L/C, D/P, D/A
    Supply Ability : 500 packs per day
    Delivery Time : 3~25 days
    • Product Details
    • Company Profile

    Dental Heat Treatment Rotary Endo Files Systems P Glider File Instrument For Root Canal Treatment

    Dental Process With Heat-Treatment Gold Color Rotary Endo Files P Glider File Is Flexible For Searching Root Canal


    S&D P Glider file

    This is the dental file used s used in endodontic treatment to expand the glide path in preparation for mechanized NiTi files.

    These instruments are to be used only by licensed clinicians.

    2.Main materials

    1) Cutting Nickel Titanium(including nickel and chromium)

    2) Shank: copper


    Purpose of use and effect -efficacy

    only be used in should be used in clockwise rotary motion only with original settings,


    Specifications

    Under the provisions of ISO 13485 performance test, product durability for twisting and bending must exceed specified value of our standard.

    #1602

    Method of manipulating or method of use

    at a speed of 300 rpm with light apical pressure, and set at 2-5.2 Ncm for torque control. 250 – 300 rpm


    Precautions for use

    1.To prevent infection, sterilize the product by autoclave and make sure sterilization is completed before using .

    2. Choose the most appropriative type for each case and follow the general method.

    3.Before using, make sure the instruments outside of oral cavity that there are no deformations, scratches and cracks .

    4. If the head of product is thin, long or large, there are possibilities for breaking or twisting. Because of this, be sure to avoid using unreasonable angle and excessive pressure.

    5.Wear safety glasses to protect your eyes from damage. Also, wear a dust protective mask to prevent inhaling dust .

    6.A chain, string, or other instrument shall be attached to the hole through the shank to prevent it from falling into the mouth.

    7. A rubber dam or gauze screen should be used to prevent accidental ingestion and aspiration. Patients with a high likelihood of accidental ingestion or aspiration should not be treated in a horizontal position and should be treated in a seated position whenever possible.

    8. Do not use this instrument for any purposes except for listed applications above.

    9.Only for use by dentists.

    10.This product should be treated as medical waste when disposed.

    11.Dispose the product if damaged or contaminated .

    12.After using, wash it with medical cleaning agent and brush, then wash away foreign substances like adherent body fluids and body tissues.

    13.Avoid using unreasonable angle and excessive pressure.

    14. This product has possibility that be corrosive if sunk into NaOCl, EDTA and etc . for a long time.


    Storages and duration of use

    1. Avoid storing at high temperature, humidity and direct sunlight.

    Keep liquids away. Store it at room temperature.

    2. Do not damage or make a pinhole to packaging materials.

    3. The product is subject to be improved without previous notice. Enforce

    the first-in first-out method for stock management.

    4. Do not store the product under a germicidal lamp to avoid deterioration.


    Maintenances and inspections

    Sterilize this product by autoclave under established method and term for each use.

    Method of sterilization:

    Put this product in a sterilization pack (or foil) and place it on a sterilization tray, or files stand for autoclave sterilization with reference to the following terms.

    Terms for sterilization:

    term(1) temperature: 134degrees Celsius time: 15 minutes or more

    2.Do not use high pressure steam sterilizer which heats more than 200 degrees Celsius including drying process .


    Instruction of using

    Before using a P-Glider file, explore the canal up to a .010 K-file.

    to follow the canal until working length is achieved.

    Quality Dental Heat Treatment Rotary Endo Files Systems P Glider File Instrument For Root Canal Treatment for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shanghai S&D International Dental Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)